hpe-Posture Analysis
Axis Rehabilitation & Fitness Center · Medical
Independent analytics for this App Store listing. AppTracker is not affiliated with Axis Rehabilitation & Fitness Center.
Chart standing · US
What changed · US
Listing changes AppTracker has observed for this app in this storefront — new versions, price moves, rating shifts, and store copy.
[NEW] Real-Time Balance Analysis • Place the device on a balance pad to measure sway live, shown on a bullseye target. • Choose both feet, left single leg or right single leg; eyes open or closed; 20, 30 or 60 seconds. • Voice and vibration cues guide the test, so it works even with the screen at floor level. • Time graphs for tilt and for anterior-posterior / medio-lateral sway, plus a 5-second segment table. • Trajectory replay and a PDF report. [NEW] Bluetooth remote shutter • Take photos and videos with a selfie-stick or ring remote button. • Supports remotes that send ordinary keys such as Enter or Space. • Works on every capture screen: posture, range of motion, body type and dynamic analysis. • Can be switched on or off in Settings, with a diagnostic display showing which key the remote sends. [IMPROVED] Pelvic tilt and knee angle assessment • Unified sex-specific normal ranges for pelvic tilt (male 4-11°, female 7-15°). • Every report now states the normal range for both sexes. • Sex is requested before the lateral posture views. • The lateral knee angle is measured on the posterior side and the arc is drawn there too. Hyperextension (back knee) is reported above 180°. • If ASIS and PSIS are not marked, pelvic assessment is skipped and trunk inclination is reported as its own item. [IMPROVED] Reports and PDF • The range-of-motion PDF is split into pages by joint region, with analysis images centred, larger and one per page. • The PDF date and file name now use the measurement date rather than the sharing date. • The app checks for a newer version at launch and offers to update. [FIXED] • Update checking did not work. • A pelvic tilt of 0° was treated as "not measured". • The pelvic value on the result screen disagreed with the diagnosis. • Landmark editing opened twice when using the camera for four-posture analysis. • Blank pages and PDF generation failures in some reports.
In-app purchases · US
What this app sells inside itself, grouped by kind and priced for this storefront.
Screenshots
Keywords this app targets
Search terms AppTracker associates with this app — estimates, not search volume. ❝ = in the app's title; a highlighted number is its current position for that term.
Similar apps
Competitors and close alternatives, as estimated by AppTracker.
About
hpe is a health & fitness app that uses AI-based Human Pose Estimation to analyze your posture and movements in real time. Key Features: • Real-time Pose Tracking: Detects and visualizes body joint points in real time via your camera. • Motion Analysis: Analyzes exercise posture accuracy to help you maintain proper form. • Joint Angle Measurement: Measures major joint angles in real time for exercise or stretching. • Workout Recording: Record sessions and track posture improvement over time. A smart posture analysis tool for fitness, sports training, and more. Subscription Info: • 1-Month Subscription: Full access to all features • 6-Month Subscription: Full access to all features • 1-Year Subscription: Full access to all features Subscriptions auto-renew 24 hours before the end of the current period. Manage or cancel in your Apple ID account settings. Terms of Use (EULA): https://www.apple.com/legal/internet-services/itunes/dev/stdeula/
What's new · 1.3.0
[NEW] Real-Time Balance Analysis • Place the device on a balance pad to measure sway live, shown on a bullseye target. • Choose both feet, left single leg or right single leg; eyes open or closed; 20, 30 or 60 seconds. • Voice and vibration cues guide the test, so it works even with the screen at floor level. • Time graphs for tilt and for anterior-posterior / medio-lateral sway, plus a 5-second segment table. • Trajectory replay and a PDF report. [NEW] Bluetooth remote shutter • Take photos and videos with a selfie-stick or ring remote button. • Supports remotes that send ordinary keys such as Enter or Space. • Works on every capture screen: posture, range of motion, body type and dynamic analysis. • Can be switched on or off in Settings, with a diagnostic display showing which key the remote sends. [IMPROVED] Pelvic tilt and knee angle assessment • Unified sex-specific normal ranges for pelvic tilt (male 4-11°, female 7-15°). • Every report now states the normal range for both sexes. • Sex is requested before the lateral posture views. • The lateral knee angle is measured on the posterior side and the arc is drawn there too. Hyperextension (back knee) is reported above 180°. • If ASIS and PSIS are not marked, pelvic assessment is skipped and trunk inclination is reported as its own item. [IMPROVED] Reports and PDF • The range-of-motion PDF is split into pages by joint region, with analysis images centred, larger and one per page. • The PDF date and file name now use the measurement date rather than the sharing date. • The app checks for a newer version at launch and offers to update. [FIXED] • Update checking did not work. • A pelvic tilt of 0° was treated as "not measured". • The pelvic value on the result screen disagreed with the diagnosis. • Landmark editing opened twice when using the camera for four-posture analysis. • Blank pages and PDF generation failures in some reports.
Details